Assessment of clinical occupational dose reduction effect of a new interventional cardiology shield for radial access combined with a scatter reducing drape

Auteur       Paddy Gilligan
Auteur       J. Lynch
Auteur       H. Eder
Auteur       S. Maguire
Auteur       E. Fox
Auteur       B. Doyle
Auteur       I. Casserly
Auteur       H. McCann
Auteur       D. Foley
Volume       86
Numéro       5
Pages       935-940
Publication       Catheterization and Cardiovascular Interventions: Official Journal of the Society for Cardiac Angiography & Interventions
ISSN       1522-726X
Date       Nov 2015
Résumé       OBJECTIVES: To assess the occupational dose reduction effect of a new interventional cardiology shield for radial access combined with a scatter reducing drape. BACKGROUND: Transradial access for catheterization has been shown to increase occupational radiation dose. Current shielding techniques are primarily based on the femoral access. This article looks at the clinical occupational combined dose reduction effect of a commercially available shield and drape which is specific to access type. METHODS: The evaluation took place in a busy interventional cardiology laboratory, with a single plane 30×40 cm flat panel detector (Siemens Artis Zee, Germany). Radiation exposure to staff was measured using electronic personal dosimeters (Unfors RaysafeAB, Sweden) placed at the collar. Patient radiation exposure was assessed using screening time and dose area product per case. Both staff and patient radiation exposure were monitored for a number of case types and operators before, during, and after deployment of the new shield and drapes. RESULTS: The cardiologists’ overall median collar badge reading per case reduced from 15.4 μSv per case without the shield/drape combination to 7.3 μSv per case with the shield drape combination in situ (P<0.001). The radiographers badge reading was reduced from 4.2 μSv per case without to 2.5 μSv per case with the shield drape combination in situ (P<0.001). There was no statistical difference in the cardiac technician’s badge reading. Patient’s dose area product was not significantly affected by the placement of the shield and drape combination. CONCLUSIONS: The shield/drape combination can significantly reduce operator exposure in a cardiac catheterization laboratory.

Export bibliographique

Chercher cette référence sur : Google Scholar, Worldcat

doi:10.1002/ccd.26009

Laisser une réponse

Vous devez etre connectez Pour poster un commentaire