Date 2007 Mai, Vol 30, Num 5 Pt 2, pp 3S66-71Revue : Journal français d'ophtalmologieType de publication : article de périodique; étude comparative;
Résumé

Noncontact tonometer (NCT) is an applanation tonometry, as is Goldmann tonometry. Numerous studies have shown the reliability of this technique but problems still exist.Noncontact tonometer (NCT) is an applanation tonometry, as is Goldmann tonometry. Numerous studies have shown the reliability of this technique but problems still exist.We measured intraocular pressure (IOP) in 340 patients (668 eyes) with NCT and Goldmann tonometer (GAT). To evaluate the influence of central corneal thickness (CCT), we classified the patients according to their CCT (<500 microm; between 520 and 580 microm, and>600 microm).Noncontact tonometer (NCT) is an applanation tonometry, as is Goldmann tonometry. Numerous studies have shown the reliability of this technique but problems still exist.We measured intraocular pressure (IOP) in 340 patients (668 eyes) with NCT and Goldmann tonometer (GAT). To evaluate the influence of central corneal thickness (CCT), we classified the patients according to their CCT (<500 microm; between 520 and 580 microm, and>600 microm).The mean difference between the two IOP measurements was -1.4 mmHg +/- 2.67 (-12 to +7), p<0,0001 for the thinner corneas, +0.13 mmHg +/- 2.67 (-8 to +8), p=0.445 for the regular corneas, and + 3.04 mmHg +/- 3.2 (-7 to +13) p<0.0001 for the thicker corneas. CCT influences NCT and GAT, but the difference between the two techniques is higher for thicker CCTs, higher IOPs, and in younger patients.Noncontact tonometer (NCT) is an applanation tonometry, as is Goldmann tonometry. Numerous studies have shown the reliability of this technique but problems still exist.We measured intraocular pressure (IOP) in 340 patients (668 eyes) with NCT and Goldmann tonometer (GAT). To evaluate the influence of central corneal thickness (CCT), we classified the patients according to their CCT (<500 microm; between 520 and 580 microm, and>600 microm).The mean difference between the two IOP measurements was -1.4 mmHg +/- 2.67 (-12 to +7), p<0,0001 for the thinner corneas, +0.13 mmHg +/- 2.67 (-8 to +8), p=0.445 for the regular corneas, and + 3.04 mmHg +/- 3.2 (-7 to +13) p<0.0001 for the thicker corneas. CCT influences NCT and GAT, but the difference between the two techniques is higher for thicker CCTs, higher IOPs, and in younger patients.NCT is good for glaucoma screening but is less reliable than GAT for glaucoma follow-up if CCT and IOP are far from regular values.

 Source : MEDLINE©/Pubmed© U.S National Library of Medicine
Accès à l'article
Exporter
Citer cet article
Que faut-il en penser? La tonométrie à air est-elle encore fiable?. Journal français d'ophtalmologie. 2007 Mai;30(5 Pt 2):3S66-71.
Courriel(Nous ne répondons pas aux questions de santé personnelles).
Dernière date de mise à jour : 31/08/2017.


[Haut de page]

© CHU de Rouen. Toute utilisation partielle ou totale de ce document doit mentionner la source.