Se connecter
Rechercher

Validation des critères d’identification des patients opérés d’un décollement de rétine rhegmatogène au CHU de Toulouse.

Auteurs : Barioulet L1, Sentis V1, Rousseau V2, Mrozek S3, Méligne D2, Fournié P1, Sommet A4, Soler V1
Affiliations : 1Unité de rétine, département d'ophtalmologie, hôpital Pierre-Paul-Riquet, CHU de Toulouse, place du Dr-Baylac, 31059 Toulouse cedex 9, France; Université Toulouse III Paul-Sabatier, 118, route de Narbonne, 31062 Toulouse, France.2Service de pharmacologie médicale et clinique, UMR Inserm 1027, CIC Inserm 1436, faculté de médecine, CHU de Toulouse, 31000 Toulouse, France.3Université Toulouse III Paul-Sabatier, 118, route de Narbonne, 31062 Toulouse, France; Anesthésie-réanimation, clinique Pasteur, avenue de Lombez, 31300 Toulouse, France; Département d'anesthésie et soins intensifs, hôpital Pierre-Paul-Riquet, CHU de Toulouse, place du Dr-Baylac, 31059 Toulouse cedex 9, France.
Voir plus >>
Date 2023 Mai 28, Vol 46, Num 5, pp 518-526Revue : Journal français d'ophtalmologieType de publication : résumé en anglais; article de périodique; DOI : 10.1016/j.jfo.2022.11.013
Résumé

Seasonal variations seem to modify the incidence of rhegmatogenous retinal detachment (RRD), with a summer peak, although the meteorological parameters involved have not been studied in France. In order to conduct a national study evaluating the association between the occurrence of RRD and various climatological variables (METEO-POC study), we need to establish a national cohort of patients having undergone surgery for RRD. The data of the National Health Data System (SNDS) allow the realization of epidemiological studies concerning various pathologies. However, as these databases were initially intended for medical administrative use, the identification of the pathologies coded in these databases must be validated before any use for research purposes. In order to carry out a cohort study using SNDS data, the objective of this study is to validate the identification criteria for patients having undergone RRD surgery at Toulouse University Hospital.We compared the cohort of RRD surgery patients at Toulouse University Hospital from January to December 2017 assembled from SNDS data with the cohort of patients meeting the same selection criteria assembled from Softalmo software data.With a positive predictive value of 82.0%, a sensitivity of 83.8%, a specificity of 69.9%, and a negative predictive value of 72.5%, we can consider that our eligibility criteria are performing well.Since the selection of patients via SNDS data is reliable at Toulouse University Hospital, we can use it at the national level for the METEO-POC study.

Mot-clés auteurs
chu de toulouse; critères d’identification; décollement de rétine rhegmatogène; identification criteria; rhegmatogenous retinal detachment; snds; snds database; toulouse university hospital;
 Source : MEDLINE©/Pubmed© U.S National Library of Medicine
Accès à l'article
  Accès à distance aux ressources électroniques :
Exporter
Citer cet article
Barioulet L, Sentis V, Rousseau V, Mrozek S, Méligne D, Fournié P, Sommet A, Soler V. Validation des critères d’identification des patients opérés d’un décollement de rétine rhegmatogène au CHU de Toulouse. Journal français d'ophtalmologie. 2023 Mai 28;46(5):518-526.
Courriel(Nous ne répondons pas aux questions de santé personnelles).
Dernière date de mise à jour : 03/06/2023.


[Haut de page]

© CHU de Rouen. Toute utilisation partielle ou totale de ce document doit mentionner la source.