Dispositifs intra-uterins au cuivre.

Auteurs : Thiery MDate 1983 Octobre, Vol 11, Num 10, pp 1131-7Revue : Contraception, fertilité, sexualitéType de publication : article de périodique;
Résumé

Following initial development of the Grafenberg ring in the 1920's, IUDs fell into disuse until the late 1950s, when plastic devices inserted using new technology began to gain worldwide acceptance. Further research indicated that copper had a significant antifertility effect which increased with increasing surface area, and several copper IUDs were developed and adapted, including the Copper T 200, the Copper T 220C, and the Copper T 380 A, probably the most effective yet. The Gravigard and Multiload are 2 other copper devices developed according to somewhat different principles. Copper devices are widely used not so much because of their great effectiveness as because of their suitability for nulliparous patients and their ease of insertion, which minimizes risk of uterine perforation. Records of 2584 women using Copper IUDs for 7190 women-years and 956 women using devices without copper for 6059 women-years suggest that the copper devices were associated with greater effectiveness and fewer removals for complications. Research suggests that the advantages of copper IUDs become more significant with increased duration of use. Contraindications to copper devices include allergy to copper and hepatolenticular degeneration. No carcinogenic or teratogenic effect of copper devices has been found, but further studies are needed to rule out other undesirable effects. Significant modifications of copper devices in recent years have been developed to increase their effectiveness, prolong their duration of usefulness, facilitate insertion and permit insertion during abortion or delivery. The upper limit of the surface area of copper associated with increased effectiveness appears to be between 200-300 sq mm, and at some point increases in copper exposure may provoke expulsion of the IUD. The duration of fertility inhibition of copper IUDs is usually estimated at 2-3 years, but recent research indicates that it may be 6-8 years, and some devices may retain copper surface for as long as 20 years. Shorter and smaller versions of standard copper IUDs have been tested as they permit easier insertion, but high rates of pregnancy, expulsion, and removal have prevented their wider use. The discovery that the size of the uterine cavity is more important than its length has prompted the development of some promising uterine measuring instruments. Attempts to develop a device appropriate for postpartum use have been disappointing, and expulsion rates remain high. A few promising new forms of copper IUDs have been developed but not yet tested clinically.

Mot-clés auteurs
Contraception; Contraception Termination; Contraceptive Effectiveness; Contraceptive Methods; Copper--beneficial effects; Copper--complications; Copper--contraindications; Evaluation; Examinations And Diagnoses; Family Planning; Ingredients And Chemicals; Inorganic Chemicals; Insertion; Iud; Iud Material; Iud; Copper Releasing; Iud; Unmedicated; Metals; Size; Treatment; Use-effectiveness;
 Source : PASCAL/FRANCIS INIST
 Source : MEDLINE©/Pubmed© U.S National Library of Medicine
Chercher l'article
Accès à distance aux ressources électroniques :
Sur Google Scholar :  En bibliothèques :
Exporter
Citer cet article
Thiery M. Dispositifs intra-uterins au cuivre. Contraception, fertilité, sexualité. 1983 Oct;11(10):1131-7.