Preferred Label : stopped flow;
IUPAC definition : A technique for following the kinetics of reactions in solution (usually in the millisecond
time range) in which two reactant solutions are rapidly mixed by being forced through
a mixing chamber. The flow of the mixed solution along a uniform tube is then suddenly
arrested. At a fixed position along the tube the solution is monitored (as a function
of time following the stoppage of the flow) by some method with a rapid response (e.g.
photometry).;
Origin ID : S06033;
See also
A technique for following the kinetics of reactions in solution (usually in the millisecond
time range) in which two reactant solutions are rapidly mixed by being forced through
a mixing chamber. The flow of the mixed solution along a uniform tube is then suddenly
arrested. At a fixed position along the tube the solution is monitored (as a function
of time following the stoppage of the flow) by some method with a rapid response (e.g.
photometry).